| Specifications |
|
|
|
| Technical Specifications |
|
Power Input
|
Natural Gas: 30,735-117,000 Btu LP Gas: 30,735-117,000 Btu
|
Minimum Flow to Activate
|
0.6 gallons per minute (gpm) |
Flow Rates
|
45°F rise @ 4.3 gpm 55°F rise @ 3.4 gpm 65°F rise @ 2.9 gpm 77°F rise @ 2.4 gpm 90°F rise @ 2.1 gpm
|
Energy Factor
|
NG: .80 LP: .80
|
Thermal Efficiency
|
NG: 80% LP: 80%
|
| Dimensions |
H: 25¾" W: 16¾" D: 8½"
|
Weight
|
33 lbs. |
Modulating Gas Valve
|
Yes
|
Ignition
|
Hydro-generated (No electricity) |
| Accessories |
Power vent for horizontal venting (AQ4) |
| Installation Specifications |
|
| Water Connection |
½" Male NPT |
| Gas Connection |
¾" Male NPT |
| Water Pressure |
Minimum: 30 PSI Maximum: 150 PSI |
| NG Pressure |
Minimum: 7" WC Maximum: 14 " WC |
| LP Pressure |
Minimum: 11" WC Maximum: 14 " WC |
| Electrical Supply |
None |
Vent Size
|
5" (double-wall type B) |
Vent Termination
|
Vertical |
|
|
|
|
|
|
| |
|
| |
|
| |